V. Trouble Shooting


AIR PROVING ERROR

•

The ICECON2 controller has
lost the Tachometer signal.

•

Check combustion blower
operation.

•

Check tachometer sensor
operation (see section
******).

•

Check ICECON2 fuses

FLAME ERROR

•

The ICECON2 controller has
lost the 24 VAC on terminal
J22.

•

Check gas supply

•

Check ignition module for
proper operation

•

Check all fail safes for
proper operation

•

Check valves, manual and
solenoid, for proper
operation

•

Check ICECON2 fuses

HIGH LIMIT ERROR

•

The ICECON2 controller has
received a temperature
reading above the factory set
value.

•

Check main blower and dampers
for proper operation.

•

Check discharge sensor for
correct attachment. Open
contacts on the Discharge
sensor terminals will cause
indication of a high limit
condition.

•

Check ICECON2 fuses

LOW LIMIT ERROR

•

The ICECON2 controller has
detected a temperature below
that set by the as the low
limit.

•

Check unit for proper
operation.

•

Check discharge sensor.
Continuity between the white
and black terminals will
return a –51 degree F signal.

•

Check ICECON2 fuses

VALVE ERROR

•

The ICECON2 controller has