Pager notification – Interlogix Concord 4 User Manual User Manual

Page 32

Advertising
background image

30

Concord 4 User Manual

Pager notification

Your system can notify up to five different pager phone numbers to report system
events. The installer can program any numeric pager to receive pages for one or
more of the following groups:

Opening and closing reports.

Latchkey reports.

Notify by exception reports.

High level reports. Includes sensor alarms, tamper, restorals, phone tests,

receiver failures, receiver jams, touchpad tampers, bus failures, freeze
alarms, freeze troubles, no activity alarms, fire panics, police panics, and
auxiliary panics.

Low-level reports. Includes bypass sensors, low battery, supervisory,

trouble, phone test, event buffer full, AC power failure, CPU low battery, auto
phone test, CPU back in service, phone failure, and touchpad low battery.

Pager messages

When an event is reported on a numeric pager, the following information is
included:

• Event code (for example, 111).

• Sensor number or user number (for example, 004).

• Last four digits of the central station account number (for example, 2228).

Although all three types of information can be reported on your pager, your pager
service determines how the information will appear.

The event code number (Table 3 below) identifies what has happened.

Table 3: Pager event code

Event code

Description

009

A sensor has been restored to it nonalarm state.

111

System has been disarmed.

115

Sensor test exit.

118

System trouble has been fixed.

119

System alarm condition has been cancelled.

222

System armed to Level 2 (stay).

333

System armed to Level 3 (away).

555

System phone/sensor test.

888

System has a trouble condition.

Advertising