Alarm monitoring features, Audible keypad tones, Sirens – Interlogix XL LCD Keypad Plus User Guide User Manual

Page 14

Advertising
background image

6

xL LCD Keypad User's Guide

21-3600E rev1.3

Alarm Monitoring Features

Depending on how the system is set up,
specific alarms may be indicated by any of the
following items:
• An alarm message will appear on specific

keypad(s);

• Keypad 'sonalerts' (beepers) may sound;
• A local siren may be triggered;

UL Listed Systems:

For UL listed systems, a local

siren must be triggered.

• An alarm message may be transmitted to a

monitoring station (and/or to a management
PC running the Director software);

UL Listed Systems:

For UL listed systems, an

alarm message must be transmitted.

• A programmable "output" may be triggered

(this can cause a horn to sound, or perform
any other type of automated 'switching'
function);

• A numeric pager may be called to let the

wearer know that a specific type of alarm has
occurred.

These actions can be fully customized for each type
of event--for each arming level that the system can
be in at any time (Off, Stay or fully ON).

Audible Keypad Tones

The following audible keypad tones
accompany keypad visual indications like
lights and screen messages.

There are 2 versions for some of the tones to
operate:

Standard: regular tone operation.

Alternative: opposite to regular operation.

New systems will use Standard Tone Operation.
Alternative tone operation must be especially
programmed by a security representative.

These tones also apply to the ones emitting
from an Arming Station. See the section on
the Arming Station Reference in this manual.

Pressing Keypad Keys/Buttons
Single short beep

Error Tones for Wrong Keys Pressed
6 short beeps

Fire Alarm
Standard and Alternative Operation:
A quick on and off tone.

Burglary Alarm, Trouble Condition
Standard Operation:
Steady continuous tone.
Alternative Operation:
Slow on off tones

Entry and Exit Delay

(tones generated when the

protected area is entered or protection is turned on
before leaving)

Standard Operation:
Slow on off tones until the last 15 seconds of
the delay when the tones speed up and become
more immediate to indicate that protection
should be turned off or exiting should be done
to prevent a false alarm.

Alternative Operation:
Continuous tone.

Entry Delay after the System has been in Alarm
or during an Alarm Condition
Standard and Alternative Operation:
Very fast on and off beeps.

Exit Delay with a Protection Point Insecure
Standard and Alternative Operation:

Fast on and off beeps

Confirm Exit Delay

(the exit delay is shortened

when the exit door is exited before the end of the exit
delay)

Standard and Alternative Operation:
Fast on and off beeps

Closing Time Soon

(a system that has a schedule

will sound a warning when the time for the protection
to turn on is approaching)

Standard and Alternative Operation:
30 minutes before the scheduled protected
area’s protection should turn on, the keypad will
make 3 short beeps. In the final 15 minutes, the
tones will gradually get faster.

Chime

(see “Function Key Reference” in this manual)

When the chime feature is turned on and a door
is opened.
Standard and alternative operation:

Three short low sounding beeps.

Advertising