Sirens

Conventional Siren

Fire Alarm: Intermittent Tone
(the same as a Fire Alarm in the previous
keypad tone details).
Burglar Alarm: Steady Tone.

Voice Siren (optional)

Fire Alarm:

Steady tone, followed by

optional voice Fire Alarm Message.
(e.g. “FIRE! FIRE! ... Leave Immediately!”)

Burglar Alarm:

On and off tone, followed

by optional voice Burglar Alarm Message.
(e.g. “Intrusion! Intrusion! ... The police have
been called, leave immediately”).

Dealing with Alarms (what to do if
the keypad is beeping)

If an alarm occurs, you must first decide if it is
a valid alarm (break-in, battery failure, etc.), or
a false alarm. If a valid alarm occurs, be sure
to notify the appropriate persons, and/or take
steps to either deal with the item yourself--if
appropriate, or get yourself and others to
safety.

Silencing a False Alarm

An authorized user can Cancel a false alarm,
disarm the system and inform the monitoring
station not to dispatch the respective
emergency service.

This feature may not be available in all areas.
Consult your local security representative / installer

for more information.

However, fire alarms can not be cancelled.
The following steps assume that you have
accidentally triggered a false alarm. If an
alarm has been generated, the LCD display
will show the alarm, and the keypad 'sounder'
will probably also be making a steady tone.

Steps:

1.

Enter your user ID
and/or password to
log into the
keypad.

2.

Select Yes to
silence the alarm.

3.

Select Yes again
to verify who you
are.

4.

Enter your PIN
when prompted.
This will signal the
monitoring facility that you want to cancel the
false alarm.

5.

To disarm area(s),
select "Off".

6.

Select Yes to turn
all areas off, if
desired.

7.

If there was a
false alarm, the
following screen
will appear.

8.

Select Ack to
acknowledge the
alarm and disarm
the system.

XXX: refers to the number for the monitored sensor
(input point) that was in alarm.

9.

Press this key to
perform another
function.

To return to the main screen (log out), press
the “ “ escape key a few times, or let the
system time-out (1 minute).

The entry tones will now stop sounding and the
selected areas are now fully disarmed.
If the Verify option is used, it must be done within 1
minute of the false alarm occurring, for the station to
acknowledge the signal.

!! In Alarm !!
Enter ID: _ _ _

Silence System?

Yes ↓No View↓

Verify User?

Yes ↓No

To Verify User
Enter PIN: _ _ _ _

Push ► for menus
↓Off ↓Stay

All Areas Off?

Yes ↓No

Area XX
Had an Alarm

xxx

: Sensor Name

Status

Ack

Disarming...
↓Next Function