xL Arming Station Lights

The optional xL Arming Station has three lights
to indicate door, system and arming status.
The following list indicates the light messages
and audible results from the Arming Station.
For detailed information on Keypad Tones, see
Audible Keypad Tones.

1

2

3

4

5

6

7

8

9

0

#

This icon

the command to silence an
alarm

on key 9 is for

9 <login>

Lights


Work Late
Light

Yellow light on solid within 15 minutes of the
scheduled closing time.

Off if the area is not scheduled or there are more
than 15 minutes to the scheduled closing time.

Door State
Light

Red light on solid if the door is locked.

Same light solid green if the door is unlocked.

Flashing red while protection turning off if there was
an alarm in the area.

Armed Light

On solid green if the area is disarmed (Off).

On solid red if the area is set to the "Stay" arming-
level (only the perimeter sensors being monitored).

Flashing red if the area is armed (On)

Tone/Siren Result

Entry / Exit Tones

Quick turning on and
off beep.

Fire Siren

A repeating tone that
turns on for 5 seconds
off for 5 seconds. After
this happens 3 times
there is a delay and
the same sequence
repeats.

Burglary Siren

Continuous tone

Bad Command

Double short beeps

Command
Accepted

Single long beep

Not authorized to
Perform Command

Double long beep