UK System Operation

The following is required to ensure conformity
with the ACPO, DD243:2002 Standard.

UL Listed Systems:

Not to be used for UL listed

systems.

If this screen displays
after disarming …
the system has had a
Confirmed Alarm and the following procedure
must be done:
Resetting Confirmed Alarms
Once a confirmed alarm occurs at a site, the
user will be able to disarm and silence the
system. The confirmed alarm strobe display, if
it is part of the system’s equipment, will also
turn off. However, arming will be blocked until
reset by an Engineer during a service call in
the following manner:

1.

The main panel cabinet must be opened to
activate the ‘tamper sensor’

2.

The system will generate a tamper alarm; the
authorized user must first silence this.

3.

Next, the Service user ID and Pin must be
entered followed by the ID and Pin of the
authorized user.

(Master end user ID and PIN default: e.g. ID: 01
or 001, PIN: 7793)

4.

Select “Reset Confirmed Alarm”.

5.

Close the main panel cabinet to secure the
tamper sensor.

If there is an attempt made to arm the system
and this reset procedure has not been done, this
screen will appear
momentarily…

External Arming Button
When attempting to arm the system and exiting
the protected area the “external arming button”
must be pressed. Failure to do so will result in a
“Failed to Exit” condition. The protection will
disarm at the end of the arming delay and a failed
to exit report will be logged in the system’s
History log.

UK and European System
Operation

UL Listed Systems:

Not to be used for UL listed

systems.

Restoring Tampers
Once a tamper condition occurs it will be
logged in the system’s History log. Any
authorized users can silence tampers

however; the following system message will
scroll on the LCD display to indicate that a
tamper condition had occurred…
This message will only appear when the
tamper condition has been restored. The
yellow “trouble” light on the keypad will also
turn off.

1.

This message can only be cleared during a
service call in the following manner.

2.

The main panel cabinet must be opened to
activate the ‘tamper sensor’

3.

The system will generate a tamper alarm; the
authorized user must first silence this.

4.

Next, the Service user ID and Pin must be
entered followed by the ID and Pin of the
authorized user.

(Master end user ID and PIN default: e.g. ID: 01
or 001, PIN: 7793)
This screen message
will display to prompt
for the master
authority user to enter their ID and Pin.
After the reset procedure has been completed,
the system Status can be checked to ensure that
the only tamper condition still displaying is the
open main panel cabinet.

5.

Close the main panel cabinet to secure the
tamper sensor.

Arming / Disarming Conditions
If at the time of arming, certain system faults are
present, arming will be blocked.
The red armed light on the keypad will only stay
on for 30 seconds from the time of any arming.
This is to prevent the condition of the system
from being easily visible.

Confirmed Alarm!
Enter ID: _ _ _

Was in Tamper!
Enter ID: _ _ _

!! Cannot Arm !!
Confirmed Alarm!

2nd Service User
Enter ID: _ _ _