Access groups – Keri Systems Doors.NET Manual User Manual

Page 161

Advertising
background image

Doors.NET Reference Manual

- 161 -

Gateway Type

PXL NXT

Mercury

Powered

NXT

Standard

Mercury

ASSA

Aperio

ASSA

WiFi/POE

Ingersoll

Rand

Intervals per Day

4

12

12

12

12

1 (a)

12

Intervals per

Week

28

50

84

84

84

n/a

84

(a) Only one interval is allowed per time schedule.

Example – A system with both PXL and NXT gateways allows only the first 32 time
schedules to be used by PXL controllers and all 64 time schedules to be used by NXT
controllers. However, the first 32 schedules must follow the PXL rules.

When using multiple concurrent gateways the software will limit the number of holiday
schedules to the lowest value of the gateways used.

Holiday Schedule Limitations

Gateway Type

PXL NXT

Mercury
Powered

NXT

Standard

Mercury

ASSA

Aperio

ASSA

WiFi/POE

Ingersoll

Rand

Holiday Schedules

3

8

8

8

8

1

8

Holidays per Sched-

ule

32

32

255

255 (a) 255 (a) 255 (b)

255 (a)

Intervals per Hol-

iday

4

6

8

8

8

1

8

(a) Total number that can be applied across all Holiday Schedules.
(b) Holiday schedules are treated the same as time schedules. Applying a holiday sched-
ule will subtract one time schedule.

Access Groups

When using multiple concurrent gateways Doors.NET allows each gateway/hardware
type to access its total number of available access groups. It does not limit access
groups to the lowest common denominator.

Access Group Limitations