New features, Program improvements, Added support for the nxt-6rk keypad reader – Keri Systems Doors.NET Manual User Manual

Page 41

Advertising
background image

Doors.NET Reference Manual

- 41 -

l

The NXT Reader requires new firmware revision 3.01.01 specifically to enable the
In/Out reader function. If this feature is not being used then the previous version of
reader firmware (v3.00.01) continues to be fully functional.

l

The Reader Interface Module (RIM) requires new firmware revision 3.02.05.

l

The 4x4 I/O Module requires new firmware revision 3.00.02.

l

The Mercury Inside gateway (MSC) requires that NXT controllers have new MSC
firmware revision 136.

NOTE: Due to networking restrictions built into the Home versions of Windows operating
systems, Doors.Net software is NOT compatible with any Home version of Windows
XP, Windows Vista, or Windows 7. Doors.NET IS compatible with the Business, Pro-
fessional, and Ultimate versions (both 32-bit and 64-bit) of Windows XP, Windows Vista,
and Windows 7.

New Features

l

Added the ability to display a photo associated with an event in the Live Events
window. When an applicable event occurs, if the cardholder screen is open a
double-click displays the cardholder record. If the cardholder screen is not open, a
tool tip with the cardholder photo, last name, first name, middle name is displayed.

l

Added the Personal Identity Verification (PIV) 75-bit format to the Wiegand library
of standard card formats.

l

Added a Block Delete cardholder feature. This is useful if a Block Enrollment is
done incorrectly and needs to be deleted and performed again, saving time in the
cardholder deletion process. Block Delete is limited to 50 credentials at a time.

l

Added support for the NXT-6RK keypad reader.

l

Added support for keypad commands when using a Wiegand keypad with NXT
controllers with Mercury Inside firmware.

l

Added support for Elevator Control when using NXT controllers with Mercury
Inside firmware.

l

Added In/Out Reader support for NXT controllers with Mercury Inside firmware.

l

Added support for ASSA Aperio wireless door locks when using NXT controllers
with Mercury Inside firmware.

l

Added support for Axis M1054 and M1103 cameras.

Program Improvements

l

Corrected an issue where the software installer unnecessarily installed the Door-
s.NET Services Tray Application on client-only installs. This application is only
needed on the host computer running the Application Server.

l

Corrected an issue with license reactivation while Internet access was unavailable
(typically done when a user adds a new licensed feature). The License Manager
would lock the program, waiting for an activation response until Internet access
was restored. The system will now allow the program to operate without the new

Advertising