LAARS Heating Systems

8A-2. CGA
Refer to page 4 for Alternate Venting Method.

8B. Electrical Connections

If the installation is new, wire the unit per the

applicable wiring diagram for line voltage (120VAC)

and control (24VAC) wiring connections.

Do not connect an external voltage source to the

HP 24 volt (T-T) wires. Install an isolation relay if

required per diagram Figure 20.

Where a HP-M2-Series in a Paloma Pak/Hytech

retrofit is connected to a single zone system, the

original transformer relay control-pak should be

removed and all field wiring connected to the unit

electrical connection junction box on the right side of

the unit. The 120VAC power input, 120VAC system

circulator output and thermostat should be wired as

outlined in figure 18.

Be sure to set the thermostat heat anticipator to

0.9 amp for single zone connection.

If a retrofit installation includes multiple zones,

any one of the options provided in this manual may be

used, or the existing transformer relay control-pak

may be utilized and re-wired according to the diagram

below. Where two wire or three wire zone valves are

used, this is the preferred wiring method on retrofits.

8C. Manufactured Home (Mobile Home)

Appliance Installation Instructions

These appliances are design certified to conform

to the requirements of ANS Z21.10.3 for installation

in manufactured homes (mobile homes) when installed

in conformance with this manual supplement and the

manual.

8C-1. APPLIANCE MOUNTING
Model HP Series appliances are provided with a

wall mounting bracket.

Model H Series appliances are provided with

mounting holes in the base. Either lag bolts or through

bolts must be used for secure attachment of the

appliance to the structure.

Model HW Series appliances are attached to the

structure by attaching angle brackets from the struc-

ture to the secured clearance brackets. See Figure 23.

Figure 22. Paloma Pak/Hytech Transformer Relay Control Pak Rewiring.

Figure 23. Mounting in Mobile Homes.