3.3 SHORT NAMES

Short name

Description

DSE7000, DSE7xxx

All modules in the DSE7000 Series

DSE7x10

All Autostart modules in the DSE7000 Series

DSE7x20

All AMF modules in the DSE7000 Series

DSE72x0

All modules in the DSE7200 series

DSE73x0

All modules in the DSE7300 series


3.4 TERMINAL SPECIFICATION


Connection type

Two part connector.

Male part fitted to module

Female part supplied in module
packing case - Screw terminal,
rising clamp, no internal spring.

Example showing cable entry and screw

terminals of a 10 way connector

Minimum cable size

0.5mm² (AWG 24)

Maximum cable size

2.5mm² (AWG 10)

NOTE : For purchasing additional connector plugs from DSE, please see the section entitled

Maintenance, Spares, Repair and Servicing elsewhere in this document.


3.5 POWER SUPPLY REQUIREMENTS


Minimum supply voltage

8V continuous

Cranking dropouts

Able to survive 0V for 50mS providing the supply was at least 10V before the
dropout and recovers to 5V afterwards.
This is more than sufficient to allow the module to operate during engine
cranking where the battery supply often falls as low as 4V (on a 12V system!)

This is achieved without the need for internal batteries or other external
requirements.

Maximum supply voltage

35V continuous (60V protection for surges)

Reverse polarity protection

-35V continuous

Maximum operating current

DSE7200 / DSE7300

160mA at 24V
340mA at 12V

Maximum standby current

DSE7200 / DSE7300

80mA at 24V
160mA at 12V


3.5.1 PLANT SUPPLY INSTRUMENTATION DISPLAY


Range

0V-70V DC (note Maximum continuous operating voltage of 35V DC)

Resolution

0.1V

Accuracy

±1% full scale (±0.7V)