2 analogue sensors – Winco DSE7300 Series User Manual

Page 33

Advertising
background image

DSE7200 / 7300 Series Operators Manual

33

4.2.2 ANALOGUE SENSORS

PIN

No

DESCRIPTION

CABLE

SIZE

NOTES

15

Sensor Common Return

0.5mm²

AWG 20

Return feed for sensors

16

Oil Pressure Input

0.5mm²

AWG 20

Connect to Oil pressure sensor

17

Coolant Temperature Input

0.5mm²

AWG 20

Connect to Coolant Temperature sensor

18

Fuel Level input

0.5mm²

AWG 20

Connect to Fuel Level sensor

19

Flexible sensor
(not available on 7200 series controller)

0.5mm²

AWG 20

Connect to additional sensor (user configurable)

NOTE:- Terminals 20 and 21 are not fitted to the 7200/7300 series controller.

NOTE:- . It is VERY important that terminal 15 (sensor common) is soundly connected to an earth

point on the ENGINE BLOCK, not within the control panel, and must be a sound electrical connection to
the sensor bodies. This connection MUST NOT be used to provide an earth connection for other terminals
or devices. The simplest way to achieve this is to run a SEPERATE earth connection from the system
earth star point, to terminal 15 directly, and not use this earth for other connections.

NOTE:- . If you use PTFE insulating tape on the sensor thread when using earth return sensors,

ensure you do not insulate the entire thread, as this will prevent the sensor body from being earthed via
the engine block.