1.3 Specifications

Analog Input (AI)

X

Programmable channels: 16 single-ended (SE) or 8 differ-
ential input (DI)

X

A/D converter: A/D7663 or equivalent

X

Maximum sampling rate: 250 kS/s

X

Resolution: 16-bit, no missing code

X

Input coupling: DC

X

Programmable input range:

X

Operational common mode voltage range: ±11V

X

Overvoltage protection:

Z

Power on: Continuous ±30 V

Z

Power off: Continuous ±15 V

X

FIFO buffer size: 1024 samples

X

Data transfers:

Z

Programmed I/O

Z

Bus-mastering DMA with scatter/gather

X

Channel Gain Queue configuration size: 512 words

Device

Bipolar input range

Unipolar input range

2204/

2208

±10 V

0 V to 10 V

±5 V

0 V to 5 V

±2.5 V

0 V to 2.5 V

±1.25 V

0 V to 1.25 V

Table 1-1: Programmable Input Range