Table 1-2, Bandwidth, Table 1-3 – ADLINK DAQe-2214 User Manual
Page 17: System noise, Table 1-4, Cmrr (dc to 60 hz)

Introduction
5
X
Bandwidth (Typical 25ºC):
X
System Noise (LSBrms, including Quantization, Typical,
25°C)
X
Input impedance:
Z
Normal power on: 1 G
Ω
/100 pF
Z
Power off: 820
Ω
Z
Overload: 820
Ω
X
CMRR (DC to 60 Hz, Typical)
Device
Input range
Small signal
bandwidth
(-3dB)
Large signal
bandwidth
(1% THD)
2206
±10 V
0 V to 10 V
760 kHz
280 kHz
±5 V
0 V to 5 V
720 kHz
300 kHz
±2.5 V
0 V to 2.5 V
610 kHz
310 kHz
±1.25 V
0 V to 1.25 V
450 kHz
330 kHz
Table 1-2: Bandwidth
Device
Input Range
System
Noise
Input Range
System
Noise
2206
±10 V
0.8 LSBrms
0 V to 10 V
0.9 LSBrms
±5 V
0.85 LSBrms
0 V to 5 V
1.0 LSBrms
±2.5 V
0.85 LSBrms
0 V to 2.5 V
1.0 LSBrms
±1.25 V
0.9 LSBrms
0 V to 1.25 V 1.2 LSBrms
Table 1-3: System Noise
Input Range
CMRR
Input Range
CMRR
±10 V
83 dB
0 V to 10 V
87 dB
±5 V
87 dB
0 V to 5 V
90 dB
±2.5 V
90 dB
0 V to 2.5 V
92 dB
±1.25 V
92 dB
0 V to 1.25 V
93 dB