ADLINK DAQe-2214 User Manual

Page 78

Advertising
background image

66

Operation Theory

Below-Low Analog Trigger Condition

Figure 4-30 shows the below-low analog trigger condition, the
trigger signal is generated when the input analog signal is less
than the Low_Threshold voltage, and the High_Threshold set-
ting is not used in this trigger condition.

Figure 4-30: Below-Low Analog Trigger Condition

Above-High Analog Trigger Condition

Figure 4-31 shows the above-high analog trigger condition, the
trigger signal is generated when the input analog signal is
higher than the High_Threshold voltage, and the
Low_Threshold setting is not used in this trigger condition.

Figure 4-31: Above-High Analog Trigger Condition