25

SSI Connector Signal Description:

SSI Timing Signal Setting

Function

SSI_TIMEBASE

Master Send the TIMEBASE out

Slave

Accept the SSI_TIMEBASE to replace the internal
TIMEBASE signal.

SSI_ADCONV

Master Send the ADCONV out

Slave

Accept the SSI_ADCONV to replace the internal
ADCONV signal.

SSI_SCAN_START

Master Send the SCAN_START out

Slave

Accept the SSI_SCAN_START to replace the internal
SCAN_START signal.

SSI_AD_TRIG

Master Send the internal AD_TRIG out

Slave

Accept the SSI_AD_TRIG as the digital trigger signal.

SSI_DAWR

Master Send the DAWR out.

Slave

Accept the SSI_DAWR to replace the internal DAWR
signal.

SSI_DA_TRIG

Master Send the DA_TRIG out.

Slave

Accept the SSI_DA_TRIG as the digital trigger signal.

Table 3-7: SSI Connector Legend