Operation Theory
65
The trigger signal is generated when the analog trigger condition
is satisfied. There are five analog trigger conditions in the DAQ-/
DAQe-2213/2214 card. The DAQ-/DAQe-2213/2214 card uses
two threshold voltages, Low_Threshold and High_Threshold to
build these different trigger conditions. You can conveniently con-
figure the trigger conditions using a software application.
Trigger level digital setting Trigger voltage
0xFF
9.92V
0xFE
9.84V
0x81
0.08V
0x80
0
0x7F
-0.08V
0x01
-9.92V
Table 4-5: Analog Trigger SRC1 (EXTATRIG) Ideal Transfer Characteristic