Operation Theory

DAQ-/DAQe-2213/2214 AI Data Format

The data format of the acquired 16-bit A/D data is two's comple-
ment coding
. Table 4-1 and Table 4-2 illustrate the valid input
ranges and the ideal transfer characteristics.

Description

Bipolar Analog Input Range

Digital

code

Full-scale Range

±10 V

±5 V

±2.5 V

±1.25 V

Least significant bit

305.2 µV

152.6 µV

76.3 µV

38.15 µV

FSR-1LSB

9.999695 V 4.999847 V 2.499924 V 1.249962 V

7FFF

Midscale +1LSB

305.2 µV

152.6 µV

76.3 µV

38.15 µV

0001

Midscale

0 V

0 V

0 V

0 V

0000

Midscale -1LSB

-305.2 µV

-152.6 µV

-76.3 µV

-38.15 µV

FFFF

-FSR

-10 V

-5 V

-2.5 V

-1.25 V

8000

Table 4-1: Bipolar Analog Input Range and Output Digital Code for DAQ/DAQe/

PXI-2205/2206

Description

Unipolar Analog Input Range

Digital

code

Full-scale Range

0V to 10 V

0 to +5 V

0 to +2.5 V 0 to +1.25 V

Least significant bit

152.6 µV

76.3 µV

38.15 µV

19.07 µV

FSR-1LSB

9.999847 V 4.999924 V 2.499962 V 1.249981 V

7FFF

Midscale +1LSB

5.000153 V 2.500076 V 1.250038 V 0.625019 V

0001

Midscale

5 V

2.5 V

1.25 V

0.625 V

0000

Midscale -1LSB

4.999847 V 2.499924 V 1.249962 V 0.624981 V

FFFF

Table 4-2: Unipolar Analog Input Range and Output Digital Code for DAQ/DAQe/