Cable setup – EXFO VDSL2 User Manual
Page 22
 
Getting Started with Copper Qualification Tests
14
AXS-200/635
Regional Settings
Cable Setup
The Cable Setup tab allows you to 
configure parameter values for the 
cable.
Each parameter and button is 
described below:
³
Cable Type defines the gauge of 
the cable in use. If wire gauge is 
measured in American Wire 
Gauge (AWG) units, the available 
choices are: AUTO, 19 AWG, 22 AWG, 24 AWG, or 26 AWG. For mm 
gauge wire, the available choices are: AUTO, 0.32 mm, 0.40 mm, 
0.50 mm, 0.60 mm, 0.65 mm, 0.80 mm, 0.90 mm, or 1.20 mm.
³
Cable Fill allows you to select the type of material the cable can be 
filled with. Changing the selection to AIRCORE, JELLY, PULP, 5 PR, or 
2 PR influences the cable capacitance per length, automatically 
updating the Cap. T/R-GND field.
³
Capacitance T-R (nF/km or nF/mi) allows you to specify a value for the 
capacitance per length constant.
³
Cap. T/R-GND (nF/km or nF/mi) allows you to specify a value for the 
capacitance per length to ground constant.
³
Resistance (Ohm/km or Ohm/mi) allows you specify a value for the 
resistance constant of the cable.
³
Attenuation (dB/km or dB/mi) allows you to specify a value for the 
reduction in signal strength or insertion loss of the cable.
³
VOP allows you to set the velocity of propagation for the cable as a 
ratio of the speed of light. Enter a value between 0.400 and 0.999.
³
Restore Defaults allows you to reset cable parameters for the selected 
cable to the standard default values.