Impulse noise, Test setup – EXFO VDSL2 User Manual
Page 92
 
VF Tests
84
AXS-200/635
Impulse Noise
Impulse Noise
The impulse noise test allows you to measure impulse noise on the circuit 
under test.
Test Setup
The Test Setup tab allows you to configure parameters for the impulse 
noise test.
Each parameter on the pane is 
described below.
³
Termination defines if the unit 
uses normal test impedance 
termination or high bridging 
impedance when the cable is 
active or terminated by other 
external equipment. For normal 
test termination select 
TERMINATED, otherwise select BRIDGING.
³
Noise Filter defines the type of noise filtering in use. If ANSI standard is 
used, the available choices are: NONE, C-MESSAGE, C NOTCHED, or 
D-FILTER. For the ITU standard, the choices are: NONE, 
PSOPHOMETRIC, P-NOTCHED, or D-FILTER
³
Low Threshold (dBm) defines the low threshold limits for the impulse 
noise test. Specify a value between -40 and 0.
³
Separation (dB) defines the level difference between the low, mid 
and high thresholds. Specify a value between 1 and 6 dB.
³
Imp. Noise Measure. Time defines the duration of the impulse noise 
test. The available choices are: 1, 5, 10, 15, 60 Minutes, or 24 Hours.