Wb test parameters – EXFO VDSL2 User Manual
Page 40
 
Auto CQ/Video-DSL Rate Prediction
32
AXS-200/635
Configuring CQ Auto Tests
WB Test Parameters
The WB Parameters tab allows you to 
set up parameters used in the 
wideband tests.
Each parameter is described below:
³
WB Noise Filter defines the level 
of wideband noise filtering. The 
available choices are: NONE, 
50 kbit, ISDN-E, HDSL-F, ADSL-G, 
ADSL, ADSL2+, VDSL, VDSL2-8, 
VDSL2-12, VDSL2-17, or VDSL2-30.
Note: VDSL2-x filters are only available if VDSL2 is enabled in the software
options.
³
Bandwidth specifies the frequency range for the test: 2.2 MHz, 
12 MHz, 17 MHz, or 30 MHz. 
Note: Frequency bands in excess of 2.2 MHz are only displayed if VDSL2 is
enabled in the software options.
³
WB Termination defines if the unit uses normal test impedance 
termination or high bridging impedance when the cable is active or 
terminated by other external equipment. For normal test termination 
select TERMINATED, otherwise select BRIDGING.
³
WB Termination Impedance defines the impedance of the dummy 
load connected to the line. Select one of the following: 100 Ohm or 
135 Ohm.
³
Imp. Noise Threshold(dBm) is the maximum impulse noise level. 
Specify a value between -50 and 0 (-40 and 0 if any filter applied).
³
Imp. Noise Measure. Time defines the time duration to measure 
impulse noise. The available choices are: 1 minute, 5 minutes, 
10 minutes, 15 minutes, 60 minutes, or 24 hours.