background image

DMM Tests

Copper, VDSL2, ADSL2+, and IP Triple-Play Test Set

67

DMM

Resistance

The Resistance tab allows you to
measure the current resistance value
and cable length for the cable
connection.

Note: If the ANSI standard is used, the tab

name Resistance changes to
Shorts Meter.

Each parameter is described below.

³

Cable Type defines the gauge of
the cable in use. If wire gauge is
measured in AWG units, the
available choices are: AUTO,
19 AWG, 22 AWG, 24 AWG, or 26 AWG. For mm gauge wire, the
available choices are: AUTO, 0.32 mm, 0.40 mm, 0.50 mm, 0.60 mm,
0.65 mm, 0.80 mm, 0.90 mm, or 1.20 mm.

³

Connection defines the type of connection to be tested. The available
choices are: Tip-Ring, Tip-Gnd, Ring-Gnd, All.

³

Temperature(F) is the temperature of the cable.

Advertising