Capacitance – EXFO VDSL2 User Manual
Page 78
 
DMM Tests
70
AXS-200/635
DMM
Capacitance
The Capacitance tab allows you to 
measure the capacitance of the loop 
and capacitance length.
If no contact fault, check the Fault 
Location test and trace for 
characteristic reflection of water.
Also check the Long. Balance tab 
for <55 dB which could indicate a 
split if no other faults detected.
Note: If the ANSI standard is used, the tab
name Capacitance changes to 
Opens Meter.
³
Cable Fill allows you to select the 
type of material the cable can be 
filled with.
³
Connection defines the type of 
connection to be tested.
³
Cap bal. thr. (nF) is the capacitance balance threshold ranging from 
0.1 to 20 nF. If the measured capacitive balance in nF is greater than 
this threshold, FAIL is displayed. Otherwise, PASS is displayed.
³
Cap bal. thr. (%) is the capacitance balance threshold ranging from 
50 to 100%. If the measured capacitance balance in percentage is 
greater than this threshold, PASS is displayed. Otherwise, FAIL is 
displayed.
³
Low cap value(nF) defines which of the above thresholds will be used 
to determine pass or fail. The range is 0.1 to 500 nF. If the loop 
capacitance is less than the Low cap value, the threshold in Cap bal. 
thr. (nF) will be used. Otherwise, the threshold in Cap bal. thr. (%) 
is used.