7 Appliance

installation

7.1

Scope of delivery

The appliance is delivered in a single carton with a document

pack and fi ttings.

i

IMPORTANT:

The fl ues package will be ordered according to the

confi guration of the installation.

Please check the contents.

1

4.6

2

2.1

2.2

2.3

2.5

2.4

3

4

4.1

4.2

4.3

4.4

4.5

Key

1

Boiler

(x1)

2

Accessories bag

(x1)

2.1 Connection

bag

(x1)

- Heating return valve

(x1)

- Cold water inlet valve

(x1)

-

Heating

fl ow valve

(x1)

- Domestic hot water connection

(x1)

- Gas isolation valve

(x1)

2.2 Hanging

bracket

(x1)

2.3

Screws and wall plugs bag

(x1)

2.4 Seals

bag

(x1)

- Flat seal ½"

(x2)

- Flat seal ¾"

(x5)

- Flat seal for cold water inlet ¾"

(x4)

2.5 PRV

pipe

(x1)

3

Wall template

(x1)

4

Documents pack

(x1)

4.1

Installation and servicing manual

(x1)

4.2 Flue

book

(x1)

4.3

Instructions for use

(x1)

4.4

Guarantee envelope pack

(x1)

4.5

Magnetic lighting instruction label

(x1)

4.6

Gas conversion label

(x1)

7.2

Recommendations before installing

7.2.1

Domestic hot water circuit design

Water pressure

The minimum working pressure to obtain the maximum domestic

fl ow is 1,0 bar.

The maximum working pressure of the domestic hot water circuit

is 10 bar. If the cold water supply pressure exceeds this, then a

pressure-reducing valve must be fi tted in the supply to the boiler.

‘Hard’ water areas

The temperatures within the heat exchanger are limited by the

boiler control system to minimise scale formation within the hot

water pipework. However, in areas where the water is ‘hard’ (i.e.

more than 200 mg/L of calcium carbonate), it is recommended

that the hot water setting is reduced and that a scale reducer is

fi tted, refer to the manufacturer’s instructions or consult the local

water company for additional advice.

Domestic water fl ow rate

The domestic hot water fl ow has a restrictor, factory fi tted, which

reduces the fl ow to a maximum of:

- 30 : 10/min,

- 35 : 12/min,

Central Heating water fl ow rate

If it is necessary to alter the fl ow rate, the system can be fi tted

with a lockable balancing valve in the main fl ow or return pipes.

- Heating circuit design

5

4

3

2

1

6

7

8

Key

1 Drain

point

2 External

bypass (if required)

3 Domestic hot water out

4 Domestic cold water supply in

5 Boiler

6 Additional expansion vessel (if required)

7 Heating return circuit

8 Heating

fl ow circuit

9 Optional

balancing

valve

INSTALLATION

- 9 -