Maintenance – Glow-worm Ultimate c User Manual

Page 38

Advertising
background image

0020167175_01 - 02/13 - Glow-worm

G31 Burner % CO

2

Model

Check (case on)

Setting (case off )

CO/CO

2

ratio

30

10.3 ± 0.3%

10.1 ± 0.2%

0.004

35

10.3 ± 0.3%

10.1 ± 0.2%

0.004

If the combustion reading is not within the acceptable values

and the integrity of the complete fl ue system and combustion

circuit seals have been verifi ed and the inlet gas pressure (and

gas rate) have been verifi ed, then, it will necessary to adjust the

combustion rate of the appliance.

i

IMPORTANT:

Adjustment is made by turning the throttle an ⅛ of a

turn, waiting 1 minute to allow the appliance to stabilise

before checking or making further adjustments.

Remove the sticker covering the “throttle” adjustment screw,

if fi tted.

Rotate the “throttle” (1) (anti-clockwise to increase), to the

required CO

2

, refer to previous diagram and the “Setting”

column in the table.

When you have fi nished, press the On/Off button to exit the

test modes.

Remove the analyser probe and replace the cap on the

sampling point, replace the controls fascia, and the front

casing panel.

i

IMPORTANT:

Remember to replace the sample point cap on

completion of the test.

17.3.4

Gas rate check

Check the gas rates as described in the commissioning

section.

17.3.5 Completion

If it is not possible to achieve the required results for either the

combustion or gas rates, it will be necessary to complete a full

service of the appliance and then repeat the combustion check

procedure. If after servicing and adjustment of the appliance

the combustion values are still unacceptable and after further

remedial work has been carried out, the appliance must be

disconnected until the CO/CO

2

ratio is acceptable.

Advice can be sought from the Glow-worm Technical Helpline.

17.4 Servicing

i

IMPORTANT:

If the annual check of combustion CO2, CO/CO2 ratio

checks did not require adjustment and the inspections

described in "Preliminaries" were satisfactory then it will

not be necessary to complete a full service.

All routine servicing requirements can be achieved by the removal

of the front panel.

Position the control box into the service position.

Before commencing with a service or replacement of parts,

isolate the boiler from the electrical and gas supplies.

17.4.1

Service interval record

Refer to benchmark Service Interval Record at the rear of this

manual.

17.5 Silencer

A

B

C

3

1

2

Key

1 Silencer retaining screw

2 Fixed

silencer

3 Removable

silencer

Remove the silencer retaining screws (1) and remove the

silencer (3).

Clean the interior of the silencer with a dry cloth if necessary,

taking care not to damage the internal foam.

Repeat the operation in reverse order to replace the silencer.

MAINTENANCE

- 36 -

Advertising