Introduction, 3 regulation and statutory requirements, 4 hydraulic schematic – Glow-worm Ultimate c User Manual

Page 6

Advertising
background image

0020167175_01 - 02/13 - Glow-worm

2.3

Regulation and statutory requirements

2.3.1 CE

Mark

This boiler meets the requirements of Statutory Instrument,

No. 3083 The Boiler (Effi ciency) Regulations, and therefore is

deemed to meet the requirements of Directive 92/42/EEC on the

effi ciency requirements for new hot water boilers fi red with liquid

or gaseous fuels.

Type test for purposes of Regulation 5 certifi ed by: Notifi ed body

1312.

Product/production certifi ed by: Notifi ed body 0086.

The CE mark indicates that the appliances described in this

manual are in compliance with the following directives:

- European directive n°2009-142 relative to gas appliances

- European directive n°2004-108 from the European Parliament

and Council relative to electromagnetic compatibility

- European directive n°2006-95 from the European Parliament

and Council relative to low voltage

- European directive n°92-42 relative to the yield of boilers

2.3.2 Local

regulations

Benchmark places responsibilities on both manufacturers

and installers. The purpose is to ensure that customers are

provided with the correct equipment for their needs, that it is

installed, commissioned and serviced in accordance with the

manufacturer’s instructions by a competent person approved

at the time by the Health and Safety Executive and that it meets

the requirements of the appropriate Building Regulations. The

Benchmark Checklist can be used to demonstrate compliance

with Building Regulations and should be provided to the

customer for future reference.

Installers are required to carry out installation, commissioning

and servicing work in accordance with the Benchmark Code

of Practice which is available from the Heating and Hotwater

Industry Council who manage and promote the Scheme.

Visit www.centralheating.co.uk for more information.

2.4 Hydraulic

schematic

15

14

13

12

11

10

9

7

8

5

6

4

3

2

1

16

17

18

19

20

21

24

23

22

26

25

27

Key

1 Gas

isolating

valve

2 Heating

fl ow isolating valve

3 Heating

safety

valve

4 Filter on cold water inlet

5 DHW

fl ow sensor

6 Water pressure sensor

7 Domestic plate to plate heat exchanger

8 Three

way

valve

9 By-pass

10 Heating return thermistor

11 Condensate

trap

12 Ignition and control electrode

13 Burner

14 Main heat exchanger

15 Thermal

fuse

16 Flue

outlet

17 Silencer

18 Heating

expansion

vessel

19 Fan

20 Gas

control

valve

21 Ignition

module

22 Heating

fl ow thermistor

23 Air

vent

24 Pump

25 Manometer

26 Heating return isolating valve

27 Domestic cold water isolating valve

A Heating

fl ow

B Pipe for heating safety valve

C Domestic hot water outlet

D Gas

E

Cold water inlet

F Heating

return

G Condensate

drain

INTRODUCTION

- 4 -

Advertising