Maintenance – Glow-worm Ultimate c User Manual

Page 39

Advertising
background image

0020167175_01 - 02/13 - Glow-worm

17.6 Expansion

vessel

1

2

Key

1 Expansion

vessel

2 Expansion vessel pressure inlet

Check the expansion vessel's supply pressure (see « Technical

Data » chapter) by means of the pressure inlet located on the

expansion vessel. Adjust the pressure if necessary.

Following the installation of a new expansion vessel, fi ll and

purge the appliance or installation, if necessary.

17.7 Condensate

trap

a

Warning:

condensate is mildly acidic. Use protective gloves.

5

3

2

4

1

6

Key

1 Condensate cleaning cap

2 Condensate

pipe

3 Condensate

outletv

4 Condensate retaining screw

5 Condensate

trap

6 Hose

Place a container under the condensate trap (5).

Remove the condensate from the reservoir (1).

Disconnect the condensation discharge (2).

Disconnect the heat exchanger hose (6).

The condense trap will contain water, lift taking care not to spill

the water.

Remove the condensate trap (5) using the retaining screw (4).

Clean the hose, the trap and the siphon, remove any

accumulated dirt.

Reassemble the components, taking care to position the

gaskets correctly.

Start the siphon (3) and fi ll with water.

MAINTENANCE