INTRODUCTION

1 Instructions

guidance

1.1 Product

documentation

The instructions are an integral part of the appliance and must be

handed to the user on completion of the installation in order to

comply with the current regulation.

Carefully read the manual, to understand all the information

to enable safe installation, use and servicing. No liability can

be accepted in the event of damage for not complying with the

guidance in this instruction manual.

These instructions consist of, Installation, Servicing, Fault Finding,

Replacement of Parts and Spares. The instructions are an integral

part of the appliance and must, to comply with the current issue of

the Gas Safety (Installation and Use) Regulations, be handed to the

user on completion of the installation.

1.2

Explanation of symbols

a

DANGER:

Risk of injuries.

e

DANGER:

Risk of electric shock.

b

ATTENTION:

Risk of damage to the appliance or to its surroundings.

i

IMPORTANT:

Important information.

1.3 Guarantee

registration

Thank you for installing a new Glow-worm appliance in your home.

Glow-worm appliances are manufactured to the very

highest standard so we are pleased to off er our customers a

Comprehensive 5 years Guarantee.

We recommend you complete and return as soon as possible

your guarantee registration card. If your guarantee registration

card is missing you can obtain a copy or record your registration

by telephoning the Glow-worm Customer Service number 01773

828100.

2 Appliance

description

2.1 Safety

devices

2.1.1 Overheating

safety

The appliance is designed to recognise the potential for an

overheat lockout and will shutdown before this happens.

2.1.2 Safety

discharge

valve

A safety discharge valve and discharge pipe are fi tted to the

boiler. This valve must not be touched.

- The heating safety valve opens when the pressure in the

heating circuit exceeds 3 bars.

Should there be any discharge from the pipe, isolate the boiler

electrical supply and call your installer or Glow-worm’s own

service organisation.

2.1.3 Frost

protection

The frost protection system operates the pump to start as soon

as the temperature in the heating circuit falls below 12°C. The

pump stops as soon as the temperature of the water contained

in the heating circuit reaches 15°C. If the temperature in the

heating system falls below 7°C, the burner ignites until it reaches

35°C. The frost-protection system is active when the appliance is

switched on. The system alone cannot ensure that the installation

is protected against frost. An separate frost thermostat is

necessary to control the temperature of the system.

a

DANGER:

Your domestic water circuit (hot or cold) is not protected

by the boiler.

2.1.4

Condensate drain blockage

During freezing conditions this may be due to the forming of ice

in the condense drain external to the house. In this case, a safety

device shuts down the appliance.

2.2 Data

label

The data label certifi es the country where the appliance is

intended to be installed.

Data label location:

1

Key

1 Data

label

a

DANGER:

The appliance shall only be connected to the gas type(s)

indicated on the data label.

Refer to chapter "Technical Data" in the technical data section

to see the defi nition of the abbreviations used on the data

label.

INTRODUCTION

- 3 -