Maintenance, 4 hydraulic block – Glow-worm Ultimate c User Manual

Page 43

Advertising
background image

0020167175_01 - 02/13 - Glow-worm

18.4 Hydraulic

block

16

9

10

8

7

6

24

17

13

12

5

4

2

1

18

19

21

22

14

15

20

23

3

25

27

26

30

30

28

29

Key

1 Three-way

valve

2 Three-way valve electrical plug

3 Three-way valve electrical plug retaining clip

4 Low water pressure sensor connector

5 Low water pressure sensor

6 Low water pressure sensor retaining clip

7 Heating

fl ow pipe retaining clip

8 Manometer

9 Manometer retaining clip

10 Heating

fl ow pipe

11 Gas

pipe

12 Flow sensor electrical plug

13 Flow

sensor

14 Heating return pipe

15 Expansion

vessel

pipe

16 Plate-to-plate heat exchanger

17 Automatic

air

vent

18 Expansion vessel pipe clip

19 Automatic air vent retaining clip

20 Pump head retaining screws

21 Pump

housing

22 Pump head connector

23 Plate-to-plate heat exchanger retaining screws

24 Safety

Discharge

Valve

25 Bypass

Valve

26 Bypass Valve retaining nut

27 Bypass Valve retaining nut

28 Impeller housing

29 Safety discharge valve plastic housing

30 Retaining clip

18.4.1

Pump (head only)

Drain the boiler heating circuit as described in the appropriate

chapter "Draining".

Disconnect the electrical plug (22) from the main board.

Remove the four cap head screws (20).

Carefully remove the pump head (21) together with cable.

Do not strain cable.

Reconnect wiring to new pump head and fi t cover.

Fit the new pump head by repeating the operations in reverse.

MAINTENANCE

- 41 -

Advertising