18.4.2 Automatic

air

vent

•

Drain the boiler heating circuit as described in the appropriate

chapter "Draining".

•

Remove the retaining clip (19). Remove the automatic air vent

(18).

•

Fit the new automatic air vent and ‘O’ ring ensuring the vent

cap is left loose.

•

Refi ll, vent and pressurise the boiler.

18.4.3

Low water pressure sensor

•

Drain the boiler heating circuit as described in the appropriate

chapter "Draining".

•

Disconnect the electrical lead (4).

•

Remove the retaining clip (6), remove the low water pressure

sensor (5).

•

Fit the new low water pressure sensor.

•

Refi ll vent and pressurise the boiler.

18.4.4 Safety

discharge

valve

•

Drain the boiler heating circuit as described in the appropriate

chapter "Draining".

•

Remove the low water pressure sensor as described in the

previous section.

•

Undo the safety discharge valve union and remove the pipe.

•

Disconnect the Central Heating isolation valve.

•

Remove the securing clips and withdraw the safety discharge

valve plastic housing (29).

•

Remove the safety discharge valve.

•

Fit new ‘O’ ring. Refi ll, vent and pressurise the boiler.

18.4.5

Flow sensor and impeller

•

Remove the the electrical connection (12).

•

Unclip the fl ow sensor (13).

•

Unscrew the impeller housing (28) and remove the impeller.

18.4.6 Bypass

•

Drain the boiler heating circuit as described in the appropriate

chapter "Draining".

•

Remove the bypass valve retaining nut (26) to remove the

bypass from its housing (25).

•

After replacing the bypass, refi ll, vent and pressurise the

boiler.

18.4.7

3 way valve motor and diverter valve

•

Drain the boiler heating circuit as described in the appropriate

chapter "Draining".

•

Disconnect the electrical plug (2).

•

Remove the retaining clip (3).

•

Remove the three way valve motor (1).

•

Remove the diverter valve retaining nut.

•

Remove the diverter valve.

•

Fit new three way valve motor and diverter valve assembly.

•

Refi ll, vent and pressurise the boiler.

18.4.8

Plate-to-plate heat exchanger

•

Drain the boiler heating and domestic hot water circuits as

described in the appropriate chapter "Draining".

•

Remove the two securing screws (23).

•

Remove the plate-to-plate heat exchanger (17).

•

When replacing the plate-to-plate heat exchanger, ensure that

the four rubber sealing washers are fi tted into the hydroblock.

NOTE: The plate-to-plate heat exchanger only fi ts one way.

•

Refi ll, vent and pressurise the boiler.