18.2 Boiler

Access

For replacement of parts, the front casing panel of the boiler will

need to be removed.

•

To remove undo the two screws on the underside of the front

casing and lift off .

18.3 Viewing

window

3

4

5

2

1

Key

1 Fibre

washer

2 Steel

washer

3 Glass

4 Steel

washer

5 Circlip

•

Remove the circlip (5).

•

Remove the steel washer (4).

•

Remove fi bre washer (1).

•

Remove the glass (3).

18.3.1 Expansion

vessel

B

C

D

E

A

3

2

1

4

2

1

Key

1 Connector

2 Expansion

vessel

3 Upper support bracket

4 Retaining

screw

5 Gasket

Drain the boiler heating circuit as described in the appropriate

chapter "Draining".

•

Remove the two screws (4).

•

Undo the connector (1) at the base of the vessel.

•

Remove upper support bracket (3).

•

Remove the expansion vessel (2).

•

Fit a new gasket between the expansion vessel and connector.

•

Refi ll, vent and pressurise the boiler.