6 Condensate Drain

INTERNAL SOIL

AND VENT STACK

DIA. 22mm MIN.

NO RESTRICTION

ON LENGTH

EXTERNAL SOIL

AND VENT STACK

DIA. 22mm MIN.

NO RESTRICTION

ON LENGTH

DIA. 22mm MIN.

EXTERNAL LENGTH

OF PIPE 3M MAX.

OPEN END OF PIPE

DIRECT INTO GULLEY

BELOW GROUND BUT

ABOVE WATER LEVEL

DIA. 22mm MIN.

NO RESTRICTION

ON LENGTH

SINK

(CONSTITUTES

AIR BREAK)

DIA. 22mm MIN.

NO RESTRICTION

ON LENGTH

SINK

OPEN END OF PIPE DIRECT INTO

GULLEY BELOW GROUND LEVEL

BUT ABOVE WATER LEVEL.

DIA. 22mm MIN.

TERMINATION FROM APPLIANCE.

EXTERNAL LENGTH OF PIPE

3M MAX.

25mm MIN.

SEAL

BOTTOM OF

TUBE SEALED

DIA. 100mm

PLASTIC TUBE

300mm

MIN.

GROUND

(either/or)

500mm MIN.

HOLE DEPTH

400mm MIN.

LIMESTONE CHIPPINGS

2 ROWS OF 3 x 12mm HOLES AT

25mm CENTRES 50mm FROM

BOTTOM OF TUBE. HOLES TO

FACE AWAY FROM HOUSE.

External Soil and Vent Pipe or Rainwater Pipe

Internal Soil and Vent Pipe

External Termination into Soakaway

Internal Termination Downstream of

Sink Waste

Internal Termination into Combined Sink Waste

External Termination to a Gulley or Hopper

*

NOTE: PIPEWORK SHOULD ALWAYS FALL AWAY FROM BOILER BY AT LEAST 2.5

44mm FOR EVERY 1M.

o

EXTERNAL

MAX. 3M

*NOTE: FOR EXTENDED

PIPE RUNS 32mm DIA.

PIPE SHOULD BE USED.

BOILER

BOILER

BOILER

BOILER

BOILER

Diagram 6.1