13 Servicing

Diagram 13.4

13344

CONTROL BOX IN SERVICE POSITION

DOMESTIC

EXPANSION

VESSEL

SERVICE SUPPORT

BRACKET

SERVICE POSITION

FILLING

LOOP

13329

13330

DOMESTIC

EXPANSION VESSEL

FLEXIBLE

HOSE

BRACKET

UNION NUT

(Do not loosen)

LOCK NUT

SECURING

SCREW

HEAT

EXCHANGER

SILENCER

13.2 Silencer

For access to the heat exchanger the silencer will need to be

removed, see diagram 13.7.
Remove the securing screw and pull the silencer from the gas

valve, this is a push fit.

13343

ELECTRODE

GASKET

SPARK GAP

4mm

SECURING

SCREW

(2 OFF)

EARTH

LEAD

13273

Diagram 13.8

Diagram 13.7

Diagram 13.5

Diagram 13.6

13.3 Spark Electrode

NOTE:

If the functional checks did not indicate poor

combustion then it is not necessary to service this

component.

Disconnect the spark electrode plug and earth lead. Remove

the two securing screws and withdraw the spark electrode

carefully from the combustion chamber, see diagrams 13.8

and 13.9.
Inspect the tips for damage.
Clean away any debris and check the spark gap is 3.5 to

4.5mm.
Check the electrode gasket for signs of damage and replace if

necessary.
NOTE: If the burner is not to be serviced, do not perform the

following instructions 13.6, 13.7, 13.8 and 13.9 but continue to

section 13.10 to complete the servicing.