Standard Horizontal Flue

10.6 Flue Length

The maximum achievable rear and side flue length for a

standard flue, diagram 10.12, is as shown in diagram 10.11.
The maximum permissible horizontal flue length is 8 metres

plus the flue terminal assembly, this can be achieved by

use of the accessories, see diagram 10.13, however should

additional 87.5o or 2 x 45o elbows be used then the length

MUST be reduced by 1metre.

When extension pipes are used the flue system must be

designed to have a continuous fall to the boiler of at least 2.5o

44mm/metre to allow condensate to run back into the boiler

and out via the condense trap & siphonic drain.
The flue can be installed from inside the building, when

access to the outside wall face is not practicable.
The diagrams below describe the lengths achievable without

the use of extensions or elbows.

10 Standard Flue - Length, Preparation and Installation

Diagram 10.11

75 min. to 586 max.
WALL THICKNESS

87min

NOTE. If necessary, it is

permitted to increase this

dimension to 600mm max.

455

145

OUTSIDE

WALL

FACE

INSIDE

WALL

L

FLUE

C

81

Max. distance from outside

wall face to min clearance.

LH - 334mm

RH - 547mm

Min. distance from outside
wall face to min clearance.

LH - 75mm

RH - 75mm

A