38

13291

CABLE STRAIN

RELIEF

SECURING

SCREW

ELECTRICAL

CARTRIDGE

Diagram 11.1

CABLE

TIES

GROMMETS

CABLE

TIES

CABLE TIES

ELECTRICAL

CABLES

13455

11 Electrical Connection

11.1 Electrical Connection

Take the previously laid electrical cable and route along the

left hand side of the tank module through the two grommets

and the cable ties and across to the installers interface as

shown in diagram 11.1.
Take the electrical cartridge from the loose items pack.
Remove the securing screw to open the cartridge.
NOTE: There are two screws supplied loose in the electrical

cartridge, these will be required to secure the cartridge into

the electrical interface housing.
Slacken the two screws of the cable strain relief in the

electrical cartridge, see diagram 11.2.
Route the mains supply and systems cables through the

strain relief and connect to the relevant plug dependant upon

your choice of system controls, refer to relevant sections 11.2

and 11.3.
Initially, if system controls are not available then fit a wire

link between “L” and “R”, this will allow the boiler to run

continuously on heating.
Fit electrical cartridge into the interface housing on completion

of the wiring, see diagram 11.3.
Secure with the two cartridge retaining screws provided in the

cartridge body.