15 Replacement of Parts

AUTOMATIC

AIR VENT

RETAINING

CLIP

13304

RETAINING

CLIP

LOW WATER

PRESSURE

SENSOR

ELECTRICAL

LEADS

LH

HYDROBLOCK

Diagram 15.19

13315

HEATING

RETURN

THERMISTOR

FAN

13310

15.23 Water Pressure Sensor

For access, refer to section 15.1.
Refer to section 15.1 and drain the boiler heating circuit.
Refer to diagram 15.19.
Disconnect the electrical lead and withdraw the lead plug.
Remove the retaining clip to remove the low water pressure

sensor.
Fit new ‘O’ ring.

15.24 Plate-to-Plate Heat Exchanger

For access, refer to section 15.1.
Refer to section 15.1 to drain the boiler heating circuit.
Refer to section 15.1 and drain the boiler domestic water

circuit.
Refer to diagram 15.20.
Remove the four screws securing the plate-to-plate heat

exchanger to the hydroblock.
There will still be water present so carefully pull the plate-to-

plate heat exchanger upwards to remove.
When replacing the plate-to-plate heat exchanger ensure that

the four rubber seals are fitted into the hydroblock.
NOTE: The plate-to-plate heat exchanger only fits one way.
Open the cold-water isolation valve and slowly open a hot

water tap to remove air.
Close the hot water tap and check for any leaks.
Open the heating circuit isolation valves, re-pressurise the
system as necessary.

Diagram 15.20