Step 3 – mount and position the reader – Datalogic Scanning Matrix 400 User Manual

Page 15

Advertising
background image

RAPID CONFIGURATION

5

1

STEP 3 – MOUNT AND POSITION THE READER


1. To mount the Matrix 400™, use the mounting brackets to obtain the most suitable

position for the reader. Two of the most common mounting configurations are shown in
the figures below. Other mounting solutions are provided in par. 3.3.

Figure 4 –Positioning with Mounting Bracket (Back)



Figure 5 –Positioning with Mounting Bracket (Side)


2. When mounting the Matrix 400™ take into consideration these three ideal label position

angles: Pitch or Skew 10° to 20° and Tilt 0°, although the reader can read a code at any tilt
angle.

P

S

T


Minimize

Assure at least 10°

Minimize

Figure 6 – Pitch, Skew and Tilt Angles

Tilt

Pitch

Skew

Pitch