5 model description, Model description, Setup (function 3) – Datalogic Scanning Matrix 400 User Manual

Page 40: Learn (function 4)

Advertising
background image

MATRIX 400™ REFERENCE MANUAL

30

2

Setup (Function 3)


Once entered, the imager automatically performs Image Acquisition parameter calibration for
the specific code presented to it.

The Setup LED will blink until the procedure is completed.

The Setup procedure ends when the Image Acquisition parameters are successfully saved in
the reader memory, the Setup LED will remain on continuously and Matrix 400™ emits 3 high
pitched beeps.

If the calibration cannot be reached after a timeout of about 5 (five) seconds Matrix 400™ will
exit without saving the parameters to memory, the Setup LED will not remain on continuously
but it will just stop blinking. In this case Matrix 400™ emits a long low pitched beep.

Learn (Function 4)


Once entered, the imager starts a procedure to automatically detect and recognize codes
which are presented to it.

The Learn LED will blink until the procedure is completed.

The Learn procedure ends when the Image Processing and Decoding parameters are
successfully saved in the reader memory, the Learn LED will remain on continuously and
Matrix 400™ emits 3 high pitched beeps.

If the calibration cannot be reached after a timeout of about 3 (three) minutes, Matrix 400™ will
exit without saving the parameters to memory, the Learn LED will not remain on continuously
but it will just stop blinking. In this case Matrix 400™ emits a long low pitched beep.

2.5 MODEL DESCRIPTION


The Matrix 400™ reader is available in different versions according to the following
characteristics:

MATRIX 400 XXX-0X0

Illuminators

0 = BS (Base, No Illuminator)

Lens

0 = C-Mount (No Lens)

Sensor Size

4 = SXGA (1280x1024)
6 = UXGA (1600x1200)

Interface

0 = Serial
1 = Ethernet


Advertising