7 external lighting systems, External lighting systems – Datalogic Scanning Matrix 400 User Manual

Page 71

Advertising
background image

CBX ELECTRICAL CONNECTIONS

61

4

4.7 EXTERNAL LIGHTING SYSTEMS


If an External Illuminator is used, it can be powered from the CBX connection box. It must be
connected to the Vdc and GND terminal clamps.

CAUTION

Power is available directly to the Illuminator, independently from the Power
Supply Switch inside the CBX.



In the case of the LT-100, LT-200 or LT-300 illuminators, one of the available digital outputs
must be connected as the control signal. In VisiSet™, configure the Output Line Function
parameter to "External Lighting System" and the Matrix Output x External Lighting System
Mode parameter to "Triggered".

Control Signal for
LT-100, LT-200 or
LT-300 illuminators

Power to External
Illuminator

Figure 72 – External Lighting System Connections



Below is a table summarizing the various External Illuminator wiring and power requirements:

Illuminator

Wire Color

CBX/Matrix Signal

Meaning

LT-100

Red

Vdc

10 to 30 Vdc

LT-200 Black

GND

Ground

Blue

O1- or O2-

Control Signal -

White

O1+ or O2+

Control Signal +

LT-300

Brown

Vdc

10 to 30 Vdc

Black

GND

Ground

Yellow/Green

Earth

Shield/Earth

Ground

Blue

O1- or O2-

Control Signal -

White

O1+ or O2+

Control Signal +

LT-210, LT-314,

White

Vdc

24 Vdc

LT-316, LT-410

Black

GND

Ground

LT-510, LT-511

Shield

Earth

Shield/Earth Ground




Advertising