4 cbx electrical connections, Cbx electrical connections – Datalogic Scanning Matrix 400 User Manual

Page 54

Advertising
background image

MATRIX 400™ REFERENCE MANUAL

44

4

4 CBX ELECTRICAL CONNECTIONS



All Matrix 400™ models can be connected to a CBX connection box through one of the
available CAB-MSxx accessory cables. These accessory cables terminate in a 19-pin
connector on the Matrix 400™ side and in a 25-pin male D-sub connector on the CBX side.

We recommend making system connections through one of the CBX connection boxes since
they offer the advantages of easy connection, easy device replacement and filtered
reference signals.

NOTE

If you require direct wiring to the reader the details of the connector pins and
relative connections are indicated in Chaper 5
.


The table below gives the pinout of the CBX100/500 terminal block connectors. Use this
pinout when the Matrix 400™ reader is connected by means of the CBX100/500:

CBX100/500 Terminal Block Connectors

Input Power

Vdc

Power Supply Input Voltage +

GND

Power Supply Input Voltage -

Earth

Protection Earth Ground

Inputs

+V

Power Source – External Trigger

I1A

External Trigger A (polarity insensitive)

I1B

External Trigger B (polarity insensitive)

-V

Power Reference – External Trigger

+V

Power Source – Inputs

I2A

Input 2 A (polarity insensitive)

I2B

Input 2 B (polarity insensitive)

-V

Power Reference – Inputs

Outputs

+V

Power Source - Outputs

-V

Power Reference - Outputs

O1+

Output 1 +

O1-

Output 1 -

O2+

Output 2 +

O2-

Output 2 -

Auxiliary Interface

TX

Auxiliary Interface TX

RX

Auxiliary Interface RX

SGND

Auxiliary Interface Reference

ID-NET™

REF Network

Reference

ID+

ID-NET™ network +

ID-

ID-NET™ network -

Shield

Network Cable Shield

Main Interface

RS232

RS485

Full-Duplex

RS485

Half-Duplex

TX

TX+

RTX+

RX

*RX+

RTS

TX-

RTX-

CTS

*RX-

SGND

SGND

SGND

* Do not leave floating, see par. 4.2.2 for connection details.