MATRIX 400™ REFERENCE MANUAL

74

5

5.5.3 ID-NET™ Network Termination


The network must be properly terminated by a 120 Ohm resistor at the first and last reader of
the network.

5.6 AUXILIARY RS232 INTERFACE


The RS232 auxiliary interface is available for Point-to-Point, Pass Through or Master/Slave
connections. When it is connected to the host computer it allows both transmission of code
data and reader configuration by VisiSet™.

The parameters relative to the aux interface (baud rate, data bits, etc.) as well as particular
communication modes such as LOCAL ECHO can be defined through the Communication
folder of the VisiSet™ utility program.

The following pins of the M16 19-pin connector are used for auxiliary interface
communication:

Pin Name

Function

O TX

Transmitted

data

S RX

Received

data

L GND

Ground


MATRIX

TX

RX

USER INTERFACE

RXD

TXD

GND

Ground

SHIELD

O

S

L

K

Earth Ground

Earth Ground

Chassis

Figure 86 - RS232 Auxiliary Interface Connections Using 19-pin Connector