MATRIX 400™ REFERENCE MANUAL

86

6

6.3 ID-NET™


The ID-NET™ connection is used to collect data from several readers to build a multi-point or
a multi-sided reading system; there can be one master and up to 31 slaves connected
together.

The slave readers are connected together using the ID-NET™ interface. Every slave reader
must have an ID-NET™ address in the range 1-31.

The master reader is also connected to the Host on the RS232/RS485 main serial interface.

For a Master/Slave Synchronized layout the External Trigger signal is unique to the system;
there is a single reading phase and a single message from the master reader to the Host
computer. It is not necessary to bring the External Trigger signal to all the readers.


In the Master/Slave Synchronized layout the Master operating mode can only be set to
Phase Mode.


The main, auxiliary, and ID-NET™ interfaces are connected as shown in the figure below.


Figure 104 – ID-NET™ M/S Synchronized Layout


Main Serial Interface (RS232 or RS485)

External Trigger

ID-NET™ (up to 16 devices - practical limit)

Host

1

3

2

Master

Slave#1

Slave#n