1 rs232 interface, Rs232 interface – Datalogic Scanning Matrix 400 User Manual

Page 56

Advertising
background image

MATRIX 400™ REFERENCE MANUAL

46

4

4.2.1 RS232 Interface


The RS232 interface can be used for Point-to-Point, Pass Through or Master/Slave
connections. When it is connected to the host computer it allows both transmission of code
data and reader configuration by VisiSet™.

The following pins are used for RS232 interface connection:

CBX100/500

Function

TX Transmit

Data

RX Receive

Data

RTS

Request To Send

CTS

Clear To Send

SGND Signal

Ground


It is always advisable to use shielded cables. The overall maximum cable length must be
less than 15 m (49.2 ft).

SGND RXD

TXD

CTS RTS

USER INTERFACE

SGND TX

RX

RTS CTS

READER

Figure 50 – RS232 Main Interface Connections Using Hardware Handshaking



The RTS and CTS signals control data transmission and synchronize the connected devices.

START

OF

TRANSMISSION

END

OF

TRANSMISSION

+ V

RTS

- V

+ V

TX DATA

- V

+ V

CTS

- V

DATA

TRANSMISSION

DATA

TRANSMISSION

C1 C2

C4

C3

C5

TRANSMISSION

STOPPED

ENABLED

DISABLED

ENABLED

IDLE

IDLE

Figure 51 - RS232 Control Signals


If the RTS/CTS handshaking protocol is enabled, the Matrix 400™ activates the RTS output
to indicate a message is to be transmitted. The receiving unit activates the CTS input to
enable the transmission.

Advertising