5.2 M12-D 4-PIN CONNECTOR (ETHERNET)


In Matrix 400 xxx-x1x models, an M12 D-Coded connector is provided for the on-board
Ethernet connection. This interface is IEEE 802.3 10 BaseT and IEEE 802.3u 100 BaseTx
compliant. See par. 5.7 for connection details.

Figure 74 - M12 D-Coded Female Ethernet Network Connector

M12 D-Coded Ethernet Network Connector pinout

Pin Name Function

1

TX +

Transmitted data (+)

2

RX +

Received data (+)

3

TX -

Transmitted data (-)

4

RX -

Received data (-)


5.3 POWER SUPPLY


Power is supplied to the reader through the pins provided on the M16 19-pin connector (see
Figure 75):

MATRIX

A

L

Vdc

GND

K

SHIELD

USER INTERFACE

CHASSIS

V- (Ground)

V+ (10 - 30 Vdc)

Earth Ground

Earth Ground

Chassis

Figure 75 - Power Supply Connection


The allowed supply voltage range is 10 to 30 Vdc.

5.4 MAIN SERIAL INTERFACE


The signals relative to the following serial interface types are available on the M16 19-pin
connector:

The main serial interface type and its parameters (baud rate, data bits, etc.) can be
defined by the user via VisiSet™ software. The RS485 half duplex is automatically set
whenever MUX32 communication protocol is enabled. For more details refer to the
"Communication" folder in the VisiSet™ Help On Line.

Details regarding the connections and use of the interfaces are given in the next paragraphs.