4.3.3 ID-NET™ Network Termination


The network must be properly terminated in the first and last reader of the network. This is
done by setting the ID-NET™ Termination Resistance Switch in the CBX100/500 to ON.

4.4 AUXILIARY RS232 INTERFACE


The RS232 auxiliary interface is available for Point-to-Point, Pass Through or Master/Slave
connections. When it is connected to the host computer it allows both transmission of code
data and reader configuration by VisiSet™.

The parameters relative to the aux interface (baud rate, data bits, etc.) as well as particular
communication modes such as LOCAL ECHO can be defined through the Communication
folder of the VisiSet™ utility program.

The 9-pin female Auxiliary Interface connector inside the CBX is the preferred connector for
device configuration or communication monitoring.

5

1

6

9

Figure 60 - 9-pin female connector


If permanent system wiring is required, the following pins are used to connect the RS232
auxiliary interface:

CBX100/500

Function

RX

Auxiliary Interface Receive Data

TX

Auxiliary Interface Transmit Data

SGND

Auxiliary Interface Reference

RX TX

Reference

USER INTERFACE

Figure 61 - RS232 Auxiliary Interface Connections


NOTE

Do not connect the Aux Interface to the CBX spring clamp connectors and
the 9-pin connector simultaneously.