MATRIX 400™ REFERENCE MANUAL

26

2

ID-NET™ M/S Multidata: Multiple stations – single reader


ID-NET™ interface allows connection of readers reading objects placed on independent
conveyors. All readers are typically located far away from each other and they use a
dedicated presence sensor.

At the end of each reading phase, each reader transmits its own data message to the host.
Thanks to ID-NET™, data collection among readers is accomplished at a high speed without
the need of an external multiplexing device. This leads to an overall cost reduction and to a
simple system wiring.

2.3.1 How To Setup/Configure the Reader Network


A complete ID-NET™ reader network can be easily setup through VisiSet™ as follows:

Mounting & Connection

1. Mechanically mount/install all the readers (refer to par. 3.2 and 3.3).

2. Wire ID-NET™ (refer to par. 4.3 or 5.5).

3. Power up the entire system.


Configuration of Slaves

1. Connect a PC equipped with VisiSet™ to the Main, Auxiliary or Ethernet interface of the

planned Slave reader.

2. Launch VisiSet™ and connect to the Slave reader.

3. From the VisiSet™ Device Menu select "Parameter Setup".

4. Set the Role of the Slave reader (Synchronized or Multidata) from the

Reading System Layout > Device Network Setting > Topology Role parameter.

5. Set the Slave Address according to the desired value 0-31 from the

Reading System Layout > Device Network Setting > Slave Address parameter. Each
reader must have a different Address on the ID-NET™ Network.

6. If necessary, set the ID-NET™ baudrate from the Reading

System

Layout >

Device Network Setting > Network Baud Rate parameter, (500 kbs default).

Advertising