6 outputs, Outputs – Datalogic Scanning Matrix 400 User Manual

Page 69

Advertising
background image

CBX ELECTRICAL CONNECTIONS

59

4

Pulled up to External
Input Device Power

Input
Signal

Input Device

Figure 67 - NPN Input 2 Using External Power


4.6 OUTPUTS


Two optocoupled general purpose outputs are available. The meaning of the two outputs
Output 1 and Output 2 can be defined by the user. They are typically used either to signal the
data collection result or to control an external lighting system.

CBX100/500

Function

+V

Power Source - Outputs

O1+

Output 1 +

O1-

Output 1 -

O2+

Output 2 +

O2-

Output 2 -

-V

Power Reference Outputs


The electrical features of the two outputs are the following:

V

CE

= 30 Vdc max.

I

CE

= 40 mA continuous max.; 130 mA pulsed max.

V

CE saturation

= 1 Vdc max. @ 10 mA

P

D

= 80 mW Max. @ 45 °C ambient temp.


By default, Output 1 is associated with the Partial Read and No Read events, which activates
when the code(s) signaled by the external trigger are not decoded, and Output 2 is
associated with the Complete Read event, which activates when all the selected codes are
correctly decoded.

The output signals are fully programmable being determined by the configured
Activation/Deactivation events, Deactivation Timeout or a combination of the two. Refer to
the Digital I/O folder in the VisiSet™ Help On Line for further details.

Advertising