4.2.3 RS485 Half-Duplex Interface

NOTE

This interface is provided for backward compatibility. We recommend using
the more efficient ID-NET™ network for Master/Slave or Multiplexer layouts.


The RS485 half-duplex (3 wires + shield) interface is used for polled communication
protocols.

It can be used for Multidrop connections with a Datalogic Multiplexer, (see par. 6.5) exploiting
a proprietary protocol based on polled mode called MUX32 protocol, where a master device
polls slave devices to collect data.

CBX100/500

Function

RTX+

RS485 Receive/Transmit Data +

RTX-

RS485 Receive/Transmit Data -

SGND Signal

Ground


RTX485+

SGND RTX485-

USER INTERFACE

SGND RTX+

RTX-

READER

Figure 54 - RS485 Half-duplex Connections


This interface is forced by software when the protocol selected is MUX32 protocol.

In a Multiplexer layout, the Multidrop address must also be set via serial channel by the
VisiSet™ utility or by the Host Programming Mode.

Figure 55 shows a multidrop configuration with Matrix 400™ readers connected to a
Multiplexer.

CAUTION

This is an example of multidrop wiring. Consult the multiplexer manual for
complete wiring instructions.