Kipp&Zonen COMBILOG Data Logger User Manual

Page 115

Advertising
background image

Coding <type of calculation>:
ASCII "0": normal calculation of average value
ASCII "1": calculation of average value with wind direction
ASCII "2": calculation of the sum over the averaging interval
ASCII "3": continuous sum
ASCII "4": vectorial average for wind velocity
ASCII "5": vectorial average for wind direction

events (b...b)

length = variable

<year>

ASCII

2 char

<month>

ASCII

2 char

<day>

ASCII

2 char

<hour>

ASCII

2 char

<minute>

ASCII

2 char

<second>

ASCII

2 char

<separation mark>

ASCII (“;“)

1 char

<average value channel 1> ASCII

8 char

<separation mark>

1

ASCII (“;“)

1 char

<average value channel n>

1

ASCII

8 char

<separation mark>

1

ASCII (“;“)

1 char

1

The response telegram will only contain these fields if

they have been defined.

The transmission of average values is performed by 8 hexa-
decimal characters in the IEE Std 754 Short Real Format (Ex-
ample: 50,3094 -> 42 49 3C D3).
Depending on the programming language being used, different
terms are used, e.g. format "single" with use of Turbo Pascal.
(refer to appendix H)