Kipp&Zonen COMBILOG Data Logger User Manual

Page 137

Advertising
background image

x ... “V“:

Universal program

y.yy :

Version

Status information

Register

Type Contents

Length

0500

ro

Module status

2 Byte

0501..0502 ro

Channel status

4 Byte

<Module status>: M16..M13 , M12..M9

= hex xy

= 1. Byte

M8..M5 , M4..M1

= hex xy

= 2. Byte

If the bit Mn in the module status is set it indicates that an error
has occurred in the sensor module, the following applies:
M1 = 1: EEPROM - Error
M2 = 1: Flash - Error
M3 = 1: ADC - Error
M4 = 1: Configuration - Error
M5 = 1: No memory card
M6 = 1: RTC - Error
M7...M16 Are currently not occupied
<Channel status>:

K32..K29 ,
K28..K25

= hex xy

= 1. Byte

K24..K21 ,

K20..K17

= hex xy = 2. Byte

K16..K13 ,

K12..K9

= hex xy = 3. Byte

K8..K5 ,

K4..K1

= hex xy = 4. Byte

If the bit Kn in the channel status is set it indicates that an error
has occurred in channel n.

Hardware Manual COMBILOG 1022

137