Parameter

Possible Values

Default Value

Description

functions this field is reserved and must be hardwired to

0x0000b. Four time value ranges are defined:
• Range A: 50 us to 10 ms

• Range B: 10 ms to 250 ms

• Range C: 250 ms to 4 s

• Range D: 4 s to 64 s
Bits are set to show timeout value ranges supported. The

function must implement a timeout value in the range

50 s to 50 ms. The following values specify the range:
• None—Completion timeout programming is not

supported

• 0001 Range A

• 0010 Range B

• 0011 Ranges A and B

• 0110 Ranges B and C

• 0111 Ranges A, B, and C

• 1110 Ranges B, C and D

• 1111 Ranges A, B, C, and D
All other values are reserved. Altera recommends that

the completion timeout mechanism expire in no less

than 10 ms.

Disable

completion

timeout

On/Off

On

Disables the completion timeout mechanism. When On,

the core supports the completion timeout disable

mechanism via the PCI Express

Device Control

Register 2

. The Application Layer logic must

implement the actual completion timeout mechanism

for the required ranges.

Error Reporting

Table 4-7: Error Reporting

Parameter

Value

Default Value

Description

Advanced

error

reporting

(AER)

On/Off

Off

When On, enables the Advanced Error Reporting (AER)

capability.

4-10